OCULUS Pentacam HR Topographer from OCULUS

$13,500.00

The OCULUS Pentacam HR is the gold standard in high-resolution corneal tomography and anterior segment analysis, providing unparalleled imaging clarity and diagnostic precision. Equipped with advanced Scheimpflug technology, Pentacam HR delivers detailed 3D imaging for corneal, cataract, and refractive surgery planning, ensuring optimal patient outcomes.

Description

The OCULUS Pentacam HR is the gold standard in high-resolution corneal tomography and anterior segment analysis, providing unparalleled imaging clarity and diagnostic precision. Equipped with advanced Scheimpflug technology, Pentacam HR delivers detailed 3D imaging for corneal, cataract, and refractive surgery planning, ensuring optimal patient outcomes.

The OCULUS Pentacam HR Topographer is a high-resolution rotating Scheimpflug camera system for anterior segment analysis that provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities.

The OCULUS Pentacam HR is a combined device consisting of a slit illumination system and a Scheimpflug camera which rotates around the eye.

A thin layer within the eye is illuminated through the slit. Being not entirely transparent the cells scatter the slit light. In doing so they create a sectional image which is then photographed in side view by a camera. This camera is oriented according to the Scheimpflug principle, thus creating an image of the illuminated plane which appears completely sharp from the anterior surface of the cornea right up to the posterior surface of the crystalline lens. Swivelling around the eye, the slit-camera device generates a series of radially oriented images of the anterior eye chamber. In the subsequent analysis of the sectional images, tissue boundaries are detected and point clouds are assigned to the various tissue layers (anterior and posterior corneal surfaces, iris, crystalline lens).

The sectional images are saved, corrected in relation to a common reference point and then put together to create a three-dimensional model of the entire anterior eye chamber. This makes it possible to generate reproducible tomographic images of the anterior eye chamber in any desired plane.

 

After correction for Scheimpflug distortion and light refraction at tissue interfaces the exact of the location of image edge points in the eye is determined by means of ray tracing. Eye movements during image acquisition are captured by a second camera (pupil camera) and also taken into account in the mathematical evaluation. This produces a set of three-dimensional measurement data which gives a precise geometric description of the anterior eye segment. This data in turn can be used to generate data on elevation, curvature, pachymetry, depth of the anterior eye chamber…etc. in the well-known form of colour maps.

Differences in brightness between individual layers provide an indication of any opacity, since transparent layers result in less slight scattering. This information can be used to assess cataracts.

The Pentacam HR is the only instrument on the market able to perform a precise and complete measurement and analysis of the centre of the cornea. The rotating measurement principle avoids measurement errors that would result from horizontal scanning. Due to the radial orientation of the sectional images the density of data points is greatest at the centre.

 

The HR Pentacam has an improved optic design and a high resolution 1.45 Mega Pixel Camera. Primary advantages are: Crisper and sharper Scheimpflug pictures allowing excellent IOL and phakic IOL implant imaging. More precise presentation of the corneal layers. Cornea imaging via a fine scan produced by 100 images in less than 2 seconds for improved accuracy. An active, shifting fixation target to allow patients with high ametropia an easy fixation.

OCULUS Pentacam HR Key Features

High-Resolution Scheimpflug Imaging – Captures precise anterior & posterior corneal measurements for superior diagnostics.
Enhanced Keratoconus & Ectasia Screening – Detects early corneal irregularities and helps assess post-LASIK ectasia risk.
Comprehensive Anterior Chamber Analysis – Measures depth, volume, and angle for glaucoma and cataract assessments.
Accurate Refractive Surgery Planning – Provides detailed corneal wavefront data for custom LASIK and IOL selection.
Fast, Non-Contact, and Patient-Friendly – High-speed scanning for efficient workflows and enhanced patient comfort.

With its high-definition imaging, automated analysis tools, and versatile clinical applications, the Pentacam® HR is the ultimate choice for ophthalmologists and refractive surgeons seeking top-tier diagnostic accuracy.

OCULUS Pentacam HR Specification

Camera digital CCD camera
Light source blue LEDs (475 nm UV-free)
Processor DSP with 400 mil. operations/s
Speed 100 images in 2 seconds
Dimensions (HxWxD) 535 x 2 80 x 36 0 mm
Weight 9 kg (without elevation table)
PC minimum requirements Pentium IV, 1.5 GHz, Windows XP, 1 GB RAM,

VGA graphic card 1024 x 768 true colour,

SB interface

 

Measurement Range

Curvature 3 – 38 mm (9 – 99 D)
Precision ± 0,1 D
Reproducibility ± 0,1 D
Operating distance 80 mm

 

OCULUS Pentacam HR Software

Basic Software:

  • Qualitative assessment of the cornea
    • Topography and elevation data of the anterior and posterior corneal surface
    • Overall pachymetry, absolute and relative
  • Glaucoma screening
    • Pachymetry based IOP correction
    • Chamber angle, -volume and –depth
  • Topography based keratoconus detection and classification
  • Indices Report to detect abnormalities
  • Comparison and differential displays
  • Superimposition of Scheimpflug images
  • Tomography
  • Automatic measurement of the corneal diameter HWTW

Optional software modules

  • Software Package Refractive – Software package designed for the Refractive surgeon with the displays and maps listed in the table chart on the previous page.
  • Software Package Cataract – Software package designed for the Cataract surgeon with the displays and maps listed in the table chart on the previous page.
  • Module Contact lens fitting – Large, unlimited pre-programmed CL database with manual editing function, fluo image simulation, mathematic best fit suggestion.
  • Module PNS (Pentacam® Nucleus Staging) and 3D lens density analysis – The density of the crystalline lens is quantified in 3D depending on the selected area. A grading factor called PNS is calculated automatically, independent of any user settings.
  • Module Belin/Ambrosio Enhanced Ectasia – This module is based on elevation maps and corneal thickness progression to detect ectasia, designed for virgin eyes.
  • Module Holladay Report – This module displays the Equivalent Keratometer Readings that are calculated considering the anterior and posterior curvature of the cornea. The distribution of the EKR’s in different zones is displayed.
  • Module phakic IOL simulation and aging prediction – This module simulates iris fixated phakic IOL position in the anterior chamber, predicts aging for up to 50 years after surgery, incl. large pre-programmed database.

 

Reference

OCULUS Pentacam brochure